The table below summarizes the basic capabilities and sensitivity limits for each mode and instrument configuration. This table was last updated for sensitivity numbers on Aug. 10, 2011.
Please refer to the links below for complete details and additional sub-system (AO & angle tracking) limits.
Mode
|
Configuration
|
Band
|
Spectral Resolution and
Point Source Limiting Magnitude for Science Camera |
---|---|---|---|
V2
|
Standard
|
H
|
H4: H < 9.0 (200 Hz frame rate) |
K
|
K5: K < 10.3 (100 Hz frame rate)
K10: K < 9.8 (100 Hz frame rate) K42: K < 7.6 (100 Hz frame rate) note: if the seeing requires a faster rate of 200Hz, the limits are 0.5 mag brighter |
||
L
|
L10: L < 6.0 (100 Hz frame rate)
shared risk |
||
Split-Pupil |
K/L
H/L |
L10: L < 4.8 (100 Hz frame rate)
and one of the following: K5 or K10 or K42 or H4, with 1.2 mag brighter limits that the standard configurations above. note: shared risk and available only during NULLING runs. |
|
Self-Phase Referenced (ASTRA-SPR) | K |
K330: 4.45 < K < 7.8
note: fringe tracking at 250 Hz and longer integrations (1Hz typical) on spectrally dispersed output |
|
Dual-Field Phase Referenced (ASTRA-DFPR) | K |
K < 14 (long integrations).
note: shared risk. |
|
Astrometry (ASTRA-Astrometry) |
K
|
K < 14 (long integrations).
note: shared risk. |
|
Nulling
|
|
N
|
N < 2.7 (2.4 Jy) best performance.
N < 3.0 (1.7 Jy) sensitivity limit. |